One thing that always gives me courage in attacking a question like this is that I figure someone has already had the problem and has come up with a solution. If you haven't adjusted your pressure switch I would check the air pressure in your tank. Basically, you start out with the tank drained. I can turn shaft with screw driver and get the same effect for 2-15 again, but like it said, even when it hums and shuts off and is completely silent, it gets hot. The well pump is 1/2 horsepower. Water pump would hum for approximately 30 seconds then stop. Only one image can be added per comment but you can post as many comments, and therefore images, as you like. - 2 line jet pump hums but doesnt turn over. That sounds like either a motor with a seizing bearing or shaft or possibly a motor that just needs a new starting capacitor. Quick TELL ALL of DRUMMOND 63407 Shallow Well pump Install |Troubleshooting | First Impressions Dad Work 48 subscribers Subscribe 14K views 1 year ago I unbox, install, and give first. There are three possibilities that could be stopping your water: When you discover you dont have any water, the first thing to check is your electrical panel. To replace the switch, start by removing the wires to the old switch and unscrewing the switch. (June 4, 2014) mike said:pump starts then in 10 to 20 seconds either kicks out or blows capacitor in control box. Adjust the pressure switch's high-limit adjustment screw with a 3/8-inch hex-head screwdriver. Check valve in nosepiece needs to be cleaned out. Keep this manual and the receipt in a safe and dry place for future reference. Then check the voltage delivered by your solar converter as well as its current capability (amps) against the pump specs. Diaphragm inside pump is split or dried up and cracked. If your pump is not operating at all, move the switch relay contacts apart from each other and check to see if there is any pitting or burning on the contacts. Lisa Here are a few important ways that you can troubleshoot common issues with shallow well pumps as they occur. replaced pump presure switch, worked ok but took awhile to pressurize but found out the 75 psi pop off valve was spewing water, when I forced the pop off valve closed it now blows breakers twice the amperage, from a 6amp to 10amp and blew a 15amp as well? With the right knowledge, you can do your best to prolong the life of your well water technology and keep it in good working order and even do some minor fixes yourself. Actuator button is stuck in the down position. Check valve placed in upside down, black o-ring goes up into the handle. Checked voltage and connections. The tank is then refilled to its maximum capacity, which is measured by the pressure gauge on the tank, and then it shuts off again. Check the water pump breaker in your electrical box to make sure the breaker hasnt tripped. Pump It Up Pump Service, Inc Having your own well gives you a few advantages over using the municipal water supply. Our water worked good for a day. I like that you said how like any other device at home, it requires care and upkeep in order to work as efficiently as you expect. Monday Friday: 7:00am 3:00pm. Even above-ground jet pumps contain a number of components that arent easy to troubleshoot without training and experience. Harbor Freight Tools Water Pump . You may also need to clean the bottom of the switch itself. a lot of snow melt and water rise lifted the pump until it fell over. You make a temporary repair to contacts by filing away the affected area, though be sure to kill all power to the pump before you do. It happened a third time this morning and I was unable to restart it. Well water pump won't start or won't run, diagnostic FAQs: This article provides answers to frequently-asked questions about water pumps or well pumps that will not start or will not run. Check the pressure gauge to make sure it isn't stuck or damaged. So then I pulled the well pump figuring it may be the check valve so I replace the check valve and reinstall the pump in the welland two weeks later it started doing the same thing again. If your pump runs nonstop, there might not be a DIY solution. If the switch thinks that you are above the cut-off pressure it won't turn on the pump. please call 1-888-866-5797 as soon as possible. Both of which cost much less than the bill for a water pump replacement. - Gary 7/15/12. Please contact the franchise location for additional information. When opened, rinse float and shell with water or alcohol. How To Check (and Replace) the Water Fill Valve, Try This Simple Tip To Fix a Slow-Filling Washer, How To Fix a Dishwasher That Doesnt Dissolve the Soap, How To Fix a Dryer That Doesnt Dry Clothes, How To Fix a Front-Loading Washing Machine That Wont Drain, How To Replace the Heating Element in an Electric Oven, How to Organize Your Freezer From Start to Finish, How DIY Furnace Maintenance Can Save a Repair Bill, We are no longer supporting IE (Internet Explorer), How to Fix the Most Common Air Conditioning Repairs Yourself, Do not Sell or Share My Personal Information. BobTake a look at the causes and cures found at WATER PUMP WON'T START. Second, check the overload protection by checking the circuit breakers and third, check if the pressure switch is damaged. Please bookmark this page to make it easy for you to check back for our response. A regular inspection from a professional is your time to ask questions, get insights, hear some first-hand knowledge and get the peace of mind of knowing youve taken steps to care for your home. My folks have been complaining about poor water pressure or no water at all for the previous two days, so I will share this information with them. This is that part of your water pump which stops water from flowing back to the well from the pressure tank. If you see a spark and the pump starts, the pressure switch is the problem. I turned breaker off checked wiring, and then turned breaker back on the pump just hummed again and smoke came out of the motor. - Michael 7/29/12. Watch out: if you're not familiar with safe, proper electrical wiring you could be shocked or killed. It's a good idea to flush out the water system after working on it. 1. However, if thats not the case, then the problem can potentially be with the water well pump itself. Lead-free fittings and drinking-water-grade rubber seals make this system appropriate for potable water. i have a question,,i have a new installed jet pump6 months,,when i flush my toilet my pump will run for maybe 20/30 seconds,,,it runs fine,,but when its right at the end,,the pressure points will snap on and off right fast 3/4 times,,i adjusted the screw and it worked good for a day now its doing the same thing,,,,runs smooth until right the end,,,then click,,click,click,. Download the troubleshooting guide that offers solutions for common issues. Depending on the type of pressure tank, it could be an indication of a higher psi, but if your tank is showing pressure, then your problem is likely within your house and not a problem with the well pump or well. So if your system pressure is below 20 psi (easily done with pump off, just run some water) then No O-rings to wear out. 100% placement assistance. My sisters good pipes appear to be having plumbing issues since she isnt getting clean water. At sea level in a perfect world, you can theoretically lift 65-degree water 34 feet with a self-primer. Frequent cycling of power to the switch and the presence of corrosive substances are two common causes. Impeller for 200 Gph utility pump. I've tried other pumps, and other outlets - same result. Turn off the power to the pressure tank as described above. You described a ruined water supply system that sounds as if it needs to be rebuilt, and what sounds like a shorted, burned-up motor or motor start capacitor or control. I have a pedrollo water pump and i have noticed that it's status light turns orange after a second of it being on. Unscrew the plastic cover from the air valve on the top of the tank. 7. If one of your lines has broken, you may notice flooding in the section of your property where the pipes go from the well to the house. Was using my hose the other day - pump shut off pressure dropped to zero. I've checked the voltage at the plug - 120 same as with power from the company. Battery damaged by use of non-Drummond charger. Not sure if your pressure switch is bad? Rubber insert has cotton plugs blocking flow. Type of Service Needed I tested it before putting it in the well and it was fine but now I cant get it to come on. As the pressure switch ages, these components can weaken and malfunction, at which time replacement is necessary. Cut out hole or replace tuging (4-000-004). The other potential problem is the setting on the pressure switch itself. Drummond Description Keep your home supplied with a steady flow of water with this 1 HP Shallow Well Pump. - When the pump motor hums but doesn't actually run. Use only power supply/charger 4-000-065 (-066 Euro; -066-A Australia; -066-E for UK). When you notice flooding, call a plumber immediately. Watch out: If the pressure really is that high the situation is dangerous as you can blow the tank or piping, causing injury. Weekends: Emergency Service Calls Only. MarkIt seems unlikely that a new pump would have a seized impeller or motor and it seems unlikely that it wouldn't be able to tolerate running briefly even if the priming operation was improper or incomplete. Still no pump start. Bad Pressure tank ? But if the breaker goes out again, call in a professional to diagnose the problem, as they will know how to tell if your well pump is bad. If your pump seems to be cycling (turning on and off repeatedly), there are a few common causes. A perfect towel. Thank you, Ben, that well pump lubrication tip may help others. Square D 9013FSG 2 pressure control switch. 26 July 2015 Josephsaid:I have a shallow well pump for irrigation. Well Pumps Shop All. My problem is that when the pressure drops through the cut in point, the switch "tries" to trip. Or the gauge is debris clogged and or faulty. Most, Verify that no GFI faults or outlets have been tripped. Handle connector tubing has a pin hole in it. This also happens if we run the faucet in the tub or the washer. Page 6: Troubleshooting Page 6 For technical questions, please call 1-800-444-3353. Andrew check the actual pressure in your system, then run water. I have a question. For those of you that dont have the desire or mechanical aptitude to do some general home repairs, give us a call for even the smallest of concerns or for a routine maintenance checkup. Sounds as if your pump has been running dry, overheating, and is in danger of being damaged; if it's not delivering water, leave it off. Choose the Right Pump Sump Removing groundwater from basements & crawlspaces Sewage Lifting sewage to a standard gravity fed sewer line Utility Removing water from pools, spas, window wells, flooded yards & roofs Transfer Moving clear water from one place to another Well Drawing clear water from shallow wells & cisterns Specialty Thanks for your help. FAX: (602) 254-2261 2023 Drummond Scientific Company. Backflow Prevention Device Testing & Repair, Laundry Center Plumbing Repairs And Installation, Trenchless Sewer Line Repair Pipe Bursting, Backflow Prevention Device Testing Repair, Factors That Affect the Life of Your Water Tank, Well Water Maintenance and Checks You Can Do Yourself, How Your Water Pump and Pressure Tank Work Together. we have well water with a pressure tank. This happens regularly but not every time. I am over it! Ken the motor could be frozen - it may be freed by a complete disassembly and cleaning of the pump motor. If this occurs, its time to buy a replacement switch. You can also measure the pump's current draw using a clamp-on ammeter. The water pressure has been dropping low then comes back for a few weeks now last night lose water all together try to prime it will kick on and suck water pressure goes up but once I put hose back on pressure drops to 0 . A regulator that operates in a range from 50 to 70 psi may operate at 60 to 80 psi if the nut is turned clockwise or 40 to 60 psi if it's turned counterclockwise. Type of Service Needed The remaining kits will have limited stock, but will be monitored closely. Moreover, if your pump already has a lot of rust in it, then the levels of iron may be high. })(); Empire Pump Corporation, formerly known as Duncan Pump and established in 1946, is a commercial water well pump company in Phoenix Arizona that specializes in the installation and rehabilitation of water well pumps and systems no matter whether your system is residential, commercial, industrial, municipal, environmental, mines, or agricultural.